Plant Growth Chamber

Technical Specification

  • Temp. Range : 10°C to 60°C
  • Temp. Accuracy : ± 0.2°C
  • Temp. Uniformity : ± 2  °C
  • Humidity Range : 40% Rh to 98% Rh
  • Humidity Accuracy : + 2 % Rh
  • Humidity Uniformity : + 3 % Rh
  • Supply : Single phase 230V AC
Standard Model (S)
Inside S.S. 304 with mirror polish & outside mild steel powder coated.
GMP Model (G)
Inside S.S. 316 with mirror polish & outside stainless steel 304 with dull buff finish.

Specification

  • Double walled construction with backside triple.
  • 3” Thick PUF Insulation ensures stable temperature with humidity & reduced energy consumption.
  • Motorized Blower at back side of the chamber develops unique air flow system which ensures maximum uniform temperature & humidity condition inside the chamber.Unique air flow assures quick recovery after door openings.
  • 1/12 HP, TEFC , F-class insulation, Single phase, 1440 RPM, 230 Volts
  • High quality U shape S.S. Tubular Heaters are used for better heating.
  • Steam injection system (Non condensing type) & reservoir tank with water level arrangement with indicator.
  • Temperature Control
    • Temperature Control : By means of Imported Microprocessor based auto tuned PID controller with CE mark & dual display of set value & process value.
    • Humidity Control
      • Humidity Control & Sensing : By means of Imported Microprocessor based auto tuned PID controller with CE mark & dual display of set value & process value with direct % RH.Direct RH electronic capacitor type humidity sensor, avoid wick cup & water.
      • Safety Features
        • Additional Safety thermostat to cut of dry heater supply in case temperature of overshoot.
        • Float switch to cutoff the wet heater supply in case of low water level. Audio & Visual alarm.
        • Compressor ON delay timer (2 min.) to safe guard the compressor.
        • In built over load protector provided for hermetically sealed compressor.
      • 50 mm validation port hole with silicon rubber seal to insert sensors for validation.
      • Full view observation Acrylic door with gasket to observe sample inside the chamber.
      • Interior illumination for Working area
      • Specially designed stainless steel rod trays ensure uniform temperature distribution.

      Models
      (S) or (G)

      Capacity
      Liters

      Internal size
      H x W x D cm

      Trays

      TI – S / G

      90

      42 x 38 x 57

      2

      TI – S / G

      170

      50 x 43 x 85

      3

      TI – S / G

      290

      56 x 47 x 112

      4

      TI – S / G

      350

      58 x 51 x 120

      5

      TI – S / G 

      450

      64 x 59 x 120

      5

      TI – S / G

      600

      68 x 61 x 146

      5

      TI – S / G

      800

      75 x 74 x 146

      7

      TI – S / G

      1000

      115 x 60 x 146

      14

      TI – S / G

      1500
      Double Door

      150 x 69 x 146

      14

      TI – S / G

      2000
      Double Door

      150 x 92 x 146

      14

      Note   : Two blowers for 400 ltrs to 2000 ltrs. Capacity chambers.

      OPTIONAL FEATURES

      • PLCfor auto change over for standby refrigeration system with HMI
      • CFR 21 part 11 compliance software for PLC with RS 485 or Ethernet communication
      • Stand by refrigeration and humidity system
      • Data Logger
      • CFR 21 part 11 compliance software for data logger
      • Data scanner complete with sensor
      • SMS Mobile alert system
      • Door access security system
      • Safety digital temperature controller
      • Digital Timer